CHAPTER 1 : OVERVIEW
5
Major
Functions
1.2 Major Functions
Color space mode (Light-source color mode)
L
v
xy, L
v
u'v', L
v
TΔuv, XYZ, L*a*b*, JND, Dominant Wavelength, Excitation
Purity, Contrast, Square ratio
(Object color mode)
L*a*b*, L*C*h, XYZ, Yxy, Hunter Lab, L*u'v', L*u*v*, Dominant Wave-
length, Excitation Purity
Notes concerning displayed values:
The CS-S10w software enhances calculation accuracy by performing internal
calculations with numbers greater in magnitude than those actually displayed.
Consequently, the least significant digit displayed may differ from that of the
instrument by one digit due to rounding or color space conversion.
Because the tolerance judgement calculation and graph-plotted points are also
processed with numbers greater in magnitude than those actually displayed, the
judgement result or plotted points may differ from those obtained with the val-
ues displayed on the instrument.
Each colorimetric value of the data measured with a spectroradiometer or
obtained by manual input of spectral data is calculated from spectral data. Each
colorimetric value of the data measured with a chroma meter or obtained by
manual input of colorimetric data is calculated from XYZ data. As a result, the
colorimetric value of the average value obtained by the manual averaging mea-
surement or by the averaging of list data may differ from the average of colori-
metric values displayed in the list.
Observer 2 degree , 10 degree
Illuminants
(Object color mode)
A, B, C, D50, D55, D65, D75, D95, E, F2, F6, F7, F8, F10, F11, F12
Up to three illuminants can be displayed simultaneously.
Measurement flow Light-source Color-Normal Mode, Light-source Color-Contrast Mode, Light-
source Color-RGB Mode, Light-source Color-RGB & Contrast Mode, and
Object Color (Varies depending on the selected document type)
Multi-Point measurement
Graph xy-chromaticity diagram, u'v'-chromaticity diagram, spectral graph,
L*a*b* absolute value, trend chart and histgram, line graph
Image display Measurement data can be linked with images (in JPEG or BMP format).
Instrument
control
functions
Measurement/Calibration
Averaging measurement: 2 to 1000 measurements
Interval measurement: 2 to 1000 measurements/0 to 12 hours interval
(in increments of 10 seconds)
Measurement with instrument key (only CS-2000/2000A or CS-200)
Downloading of configuration data to the instrument
Uploading of data stored in instrument memory
User Calibration
Tar g et Two or more pieces of target data can be registered.
Target data can be downloaded to the instrument.
Data list Listing of target data and sample data
Editing (delete, sort, average, copy & paste)