Solution ID
0
Solution Usage
TAUS0645859EN*
Description
Power on with switch off. When plugging in the copier it attempts to power up even if the main switch is turned off. About 10 seconds after plugging in the
machine it will turn off again.
Solution
CAUSE: PWB-C malfunction.
SOLUTION: The key to diagnosing this problem is unplugging the copier, then with the power switch in the off position plugging the machine back in. PWB-C
probably needs to be replaced.
Solution ID
0
Solution Usage
TAUS0645866EN*
Description
The EDH-3 is feeding multiple sheets.
Solution
CAUSE: Inadequate separation.
SOLUTION: A new separator pad and mylar have been made available as field replacement parts to improve separation performance. Please refer to
bulletin 3379 for details.
Note:
To view the above PDF, Acrobat* Reader must be installed. Acrobat Reader can be downloaded for free from the Adobe* web site at:
[[http://www.adobe.com/products/acrobat/readstep2.html| URL http://www.adobe.com/products/acrobat/readstep2.html]]
* Trademark ownership information
Solution ID
0
Solution Usage
TAUS0645869EN*
Description
How to disable scanning to Fiery controllers.
Solution
On the Di450, Di470, or Di550 change the peripheral mode to 1. This disables scanning to the Pi5500 and the Pi5501.
Solution ID
0
Solution Usage
TAUS0645879EN*
Description
Code C-004E, power supply unit cooling fan motor 1's failure to turn.
Solution
PROBABLE CAUSES:
1. Poor connection on PWB-C. If the code appears intermittently, check to see that all the fuse holders on PWB-C are making good contact with the fuses.
2. Failure of M16 or PWB-C. If the code is persistent, please see page T-42 of the Field Service Manual (approx. 4 MB) for additional details and replace
M16 or PWB-C.
Note:
To view the above PDF, Acrobat* Reader must be installed. Acrobat Reader can be downloaded for free from the Adobe* web site at:
[[http://www.adobe.com/products/acrobat/readstep2.html| URL http://www.adobe.com/products/acrobat/readstep2.html]]
* Trademark ownership information
Solution ID
0
Solution Usage
TAUS0645887EN*
Description
C-0400 (exposure lamp's failure to turn on) or C0420 (exposure lamp turning on at abnormal timing) is displayed.
Solution
27
Copyright 2007, Konica Minolta Business Solutions U.S.A., I nc.
September 2007
Comentarios a estos manuales